Troubleshooting
41│Page
PROBLEM SOLUTIONS
‐WATERHEATER‐
Unitdoesnotignitewhen
watergoesthroughthe
unit.
Istheflowrateover0.5GPM?(p.36)
Checkforthefilteroncoldwaterinlet.(p.39)
Checkforreverseconnectionandcrossconnection.
Ifyouusetheremotecontroller,isthepowerbutton
turnedon?
Thefanmotorisstill
spinningafteroperation
hasstopped.
Thisisnormal.Afteroperationhasstopped,thefanmotor
keepsrunningfor35secondsinordertore‐ignitequickly,
aswellaspurgealltheexhaustgasoutoftheflue.
Unitsoundsabnormal
whileinoperation
Contactthemanufacturerat1‐877‐737‐2840.
‐Remotecontroller:
9007606005(TM‐RE30)
(OPTIONAL)‐
Remotecontrollerdoesnot
displayanythingwhenthe
powerbuttonisturnedon.
PresstheON/OFFbuttonontheremote.
IftheLEDlightsup⇒
Thisisnormal.Whentheunithasnotoperatedforfive
minutesormore,thedisplayturnsofftoconverseenergy.
IftheLED
doesnotlight⇒
Makesuretheunithaspowersupply.
Makesurethecon nectionto theunitiscorrect.(p.23)
AnERRORcodeis
displayed.
Pleaseseep.42.
‐EASY‐LINKSYSTEM‐
Howaretheunitnumbers
assigned?
ForanEasy‐Linksystem,theParentunitisalwayslabeled
#1andallothersubsequenceChildunitsarenumbered
randomly.
TocheckwhichnumbersareassignedtowhichChildunits,
pushthebuttononthecomputerboardofanyChildunit
as
shownbelow.Theunitnumberwillbedisplayedonthe
3‐digit7‐Seg.LED.
Buttontocheck
unitnumbers
3‐digit7‐Seg.LED