Installation
22Page
The condensate drain is at atmospheric pressure (nonpressurized) and
therefore must be allowed to drain freely with gravity only.Please ensure
thattherearenoblockagesalongthecondensatedraintube.Allportionsof
the condensate drain (neutralizer and drain tube) must be at a lowe r
elevationthanthewater
heatertopreventcondensatewaterfrombuilding
upinsidetheheatexchanger.
Condensate cannot be effectively neutralized if the neutralizer elements
inside the Neutralizer accessory have been completely consumed .If this
happens, Condensate will remain acidic and can possibly cause damage to
itemssuchaspipes,concrete,etc.,ifdrainedimproperly.
TheNeutralizercartridgeisdesignedtolastfor3yearsbeforereplacement.
However,theactuallifeoftheneutralizermayvary,dependingonthe
applicationandusage.Pleaseensurethatthecartridgeisproperlyreplaced
beforetheneutralizerelementshavebeencompletelyconsumed.
Allpreventativemeasuresandsafetypracticesmustbeadheredtowhen
drainingcondensate.Themanufacturerwillnotberesponsibleforany
damagecausedbycondensate.
Adrainpan,orothermeansofprotectionagainstwaterdamage,isrequired
tobeinstalledunderthewaterheaterincaseofleaks.
Followtheelectricalcoderequirementsofthelocalauthorityhaving
jurisdiction.Intheabsenceofsu chrequirements,followthelatesteditionof
theNationalElectricalCodeANSI/NFPA70intheU.S.orthelatesteditionof
CSAC22.1CanadianElectricalCode,Part1,inCanada.
Whenservicingorreplacingpartswithinthewaterheater,labelallwires
priortodisconnectiontofacilitateaneasyanderrorfreereconnection.
Wiringerrorscancauseimproperanddangerousoperation.Verifyproper
operationafterservicing.
ELECTRICALCONNECTIONS
1. Thewaterheatermustbeelectricallygrounded.Donotattachthegroundwire toeitherthegasor
thewaterpiping.
2. Thewaterheaterrequires120VAC/60Hzelectricalpowersupplythatisproperlygrounded.
A proper disconne ct (i.e. on/off switch, power plug, etc.) controlling the main power to the
waterheatermustbeprovidedforservicereasons.(Mustcomplywithlocalcodes).
Connectthepowersupply
tothewaterheaterexactlyasshowninthewiringdiagram;
3. Agreenscrewisprovidedinthejunctionboxtogroundtheconnection.
4. Canbehardwiredorwiredtoaplugin.
5. The use of a surge protector is
recommended in order to
protect the unit
from power
surges.
WARNING
WARNING
CAUTION
ConnectPowersupply
120 VAC/60 Hz
Ground