NormalOperation
38Page
Onlypipeswithinthewaterheaterareprotectedbythefreezeprotection
system.Anywaterpipes(hotorcold)located outsidetheunitwillnotbe
protected.Properlyprotectandinsulatethesepipesfromfreezing.
HouseholdFlowRates
TakenfromUPC2006
FLOW
Theflowratethrou gh thewaterheaterislimitedtoamaximumof9.0GPMforthe520(TH2)
models,and8.0GPMforthe320(TH2S)models.
Thetemperaturesetting,alongwiththesupplytemperatureofthewaterwilldeterminetheflow
rateoutputofthe
unit.
Pleaserefertothetemperaturevs.gallonsperminutechartonp.50todeterminethelikelyflow
ratesbasedonyourlocalgroundwatertemperatureandyourdesiredoutletwatertemperature
combination.
BasedontheUnitedStatesDepartmentofEnergy
methodoftestingwaterheateroutput,
the520(TH2)
modelsisratedfor282gallons perhour(GPH)or4.8
gallonsperminute(GPM)forNaturalGas,andthe320
(TH2S)modelsisratedfor255gallonsperhour(GPH)or
4.3gallonsperminute(GPM)forNaturalGas,when
raisingthewatertemperatureby
77F(from58Fto
135F).
Refertothecharttotherightfortypicalhousehold
plumbingfixtureflowratestodeterminewhatthewater
heatercandoinahouseholdapplication.
FREEZEPROTECTIONSYSTEM
Thisunitcomesequippedwithheatingblockstoprotectitagainstdamagesassociatedwithfreezing.
Forthisfreezeprotectionsystemtooperatetherehastobeelectricalpowertotheunit.Damageto
the heat exchanger caused by freezing temperatures due to power loss is not covered under the
warranty.Incaseswherepowerlossescanoccur,considertheuseofabackuppowersupply.
Thefreezeprotectionsystemwillactivatewhenthesurroundingand/oroutsidetemperaturesdrop
below36.5°F(2.5°C).
In any areas subject to freezing temperatures, the manufacturer highly recommends an indoor
installationwiththe
DirectVentIndoormodels.Insuchanin stallation ,freezingissuescanonlyoccur
ifcoldairentersthroughtheventingintotheheatexchanger,whetherbynegativepres sureswithin
theinstallationlocationorbystrongoutsidewinds.Itistheinstaller’sresponsibilityto beawareof
theseissues and takeall
preventative measures.Themanufacturer will not be responsible for any
damagetotheheatexchangerasaresultoffreezing.
The manufacturer also highly recommends the use of a back flow vent damper to minimize the
amountofcoldairenteringthroughtheexhaustventingwhenthewaterheater
isoff.
Ifyouwillnotbeusingyourheaterforalongperiodoftime:
1. Completelydraintheunitofwater.Refertop.39.
2. Disconnectpowertoyourheater.
Thiswillkeepyourunitfromfreezingandbeingdamaged.
Appliance/Use FlowRate(GPM)
LavatoryFaucet 1.0
BathTub 4.010.0
Shower 2.0
KitchenSilk 1.5
Dishwasher 1.5
Washingmachine 4.0
CAUTION