17
FOR YOUR INFORMATION
START UP CONDITIONS
DRAFT HOOD OPERATION
Check draft hood operation by performing a worst case
depressurization of the building. With all doors and windows closed,
and with all air handling equipment and exhaust fans operating such
as furnaces, clothes dryers, range hoods and bathroom fans, a match
ame should still be drawn into the draft hood of the water heater with
its burner ring. If the ame is not drawn toward the draft hood, shut
off water heater and make necessary air supply changes to correct.
CONDENSATION
Whenever the water heater is lled with cold water, some condensate will
Never allow small children to use a hot water tap, or to draw their own
bath water. Never leave a child or handicapped person unattended
in a bathtub or shower.
NOTE: A water temperature range of 120°F-140°F (49°C-60°C) is
recommended by most dishwasher manufacturers.
The thermostat of this water heater has been factory set at its lowest
position (PILOT LIGHTING). It is adjustable and must be reset to
the desired temperature setting to reduce the risk of scald injury.
The mark (
) indicative of approximately 120°F (49°C) is preferred
starting point. Some States have a requirement for a lower setting.
Turn the water temperature dial clockwise (
) to decrease the
temperature, or counterclockwise (
) to increase the temperature.
Should overheating occur or the gas supply fail to shut off, turn off
the manual gas control valve to the appliance.
FIGURE 15.
Short repeated heating cycles caused by small hot water uses can
cause temperatures at the point of use to exceed the thermostat setting
by up to 30°F (16.7°C). If you experience this type of use you should
consider using lower temperature settings to reduce scald hazards.
Any water heater’s intended purpose is to heat water. Hot water is
needed for cleansing, cleaning, and sanitizing (bodies, dishes, clothing).
Untempered hot water can present a scald hazard. Depending on the
time element, and the people involved (adults, children, elderly, in rm,
etc.) scalding may occur at different temperatures.
HOTTER WATER CAN SCALD: Water heaters are intended to
produce hot water. Water heated to a temperature which will satisfy
space heating, clothes washing, dish washing, and other sanitizing
needs can scald and permanently injure you upon contact. Some
people are more likely to be permanently injured by hot water than
others. These include the elderly, children, the in rm, or physically/
mentally handicapped. If anyone using hot water in your home
ts into one of these groups or if there is a local code or state law
requiring a certain temperature water at the hot water tap, then you
must take special precautions. In addition to using the lowest possible
temperature setting that satis es your hot water needs, a means such
as a mixing valve should be used at the hot water taps used by these
people or at the water heater. Mixing valves are available at plumbing
supply or hardware stores, see Figure 2. Follow manufacturers
instructions for installation of the valves. Before changing the factory
setting on the thermostat, read the “Temperature Regulation” section
in this manual, see Figures 15 and 16.
TEMPERATURE REGULATION
VERY HOT= approx. 160°F (71°C)
About 1/2 second
C = approx. 150°F (66°C) About 1-1/2 seconds
B = approx. 140°F (60°C) Less than 5 seconds
A = approx. 130°F (54°C) About 30 seconds
= approx. 120°F (49°C) More than 5 minutes
LOW = approx. 80°F (27°C) - - - - - - - - - - - - - - - -
FIGURE 16.
form while the burner is on. A water heater may appear to be leaking
when in fact the water is condensation. This usually happens when:
a. A new water heater is lled with cold water for the rst time.
b. Burning gas produces water vapor in water heaters, particularly
high ef ciency models where ue temperatures are lower.
c. Large amounts of hot water are used in a short time and the re ll
water in the tank is very cold.
Moisture from the products of combustion condense on the cooler
tank surfaces and form drops of water which may fall onto the burner
or other hot surfaces to produce a “sizzling” or “frying” noise.
Excessive condensation can cause pilot outage due to water running
down the ue tube onto the main burner and putting out the pilot.
Temperature
Settings
Time to Produce 2nd & 3rd
Degree Burns on Adult Skin